Ra and Rz describe different profile properties. Ra is an arithmetic mean of absolute profile-height deviations from the mean line over the evaluation basis; Rz emphasizes peak-to-valley characteristics defined by the chosen standard and evaluation method.

One roughness number cannot describe every surface characteristic
A surface with mostly smooth texture but one pronounced groove may have a moderate Ra while showing a more consequential Rz. Two surfaces with the same Ra can behave differently in sealing, sliding or fatigue applications.
Technical method

Do not use a fixed conversion factor between Ra and Rz. Ratios vary with manufacturing process, profile shape, filtering, sample length and standard definition.
Worked situation and interpretation
A drawing that states only ‘Rz 6.3’ without indicating the relevant standard or measurement conditions may need clarification before acceptance. Trace the exact drawing requirement and the instrument’s configured parameter.
Why the common shortcut fails

Feed, nose radius, tool wear, chatter and workholding influence machined texture. A theoretical turning finish formula is not a substitute for an actual measured profile.
Where judgment is required
Use a calibrated suitable instrument, define inspection location and direction, and compare results against the correct specification. For critical surfaces, geometry and functional requirements matter beyond a single roughness value.
Verifying a surface roughness requirement
- Read the specified parameter, units, standard and sampling conditions.
- Distinguish the Ra requirement from any Rz or peak-to-valley limits.
- Select a calibrated instrument and appropriate evaluation direction and length.
- Record the measured result and process condition against the drawing revision.
How to document the result
Record the exact roughness parameter from the drawing, including whether it specifies Ra, Rz or another quantity, the unit (typically micrometers or microinches), measurement direction and specified sampling or evaluation conditions. Ra is an arithmetic mean of absolute deviations of a filtered profile; Rz characterizes profile height using a standard-dependent definition. They are not interchangeable by a fixed conversion factor.
Why an Ra value cannot simply be converted into Rz
Two surfaces may have similar average roughness while one contains a few deep grooves. Their Ra values can be close while their peak-to-valley characteristics differ substantially. Surface lay, scratches and process marks therefore matter beyond one averaged number. A calculated ball-nose scallop height is a geometric step-over estimate, not a measurement of either parameter.
Use an appropriate calibrated profilometer or approved optical method with suitable filtering and evaluation settings. Keep the measurement trace and instrument settings when required, and compare directly against the drawing requirement. For geometry-only comparisons, consult the surface finish calculator without treating its output as a measured Ra or Rz.
For connected manufacturing references, see Shop References, the Inspection Report Template and the practical guides. Choose the relevant standard and instrument before treating any example as a production rule.
Technical review note: Examples are for education and may simplify underlying standards. Engineering acceptance requires the applicable drawing, specification, calibrated methods and authorized review.
Frequently Asked Questions
Are Ra and Rz interchangeable roughness values?
No. They characterize different aspects of a surface profile and cannot be converted with a universal fixed ratio.
Why must a surface-finish standard be specified?
Parameter definitions, filtering, sampling and evaluation procedures affect the reported result, especially for Rz.
Can visual appearance confirm an Ra requirement?
No. Use the specified measuring method and traceable instrument suitable for the surface and tolerance.