An assembly clearance or fit is affected by several dimensional contributors. Stack-up analysis models how those contributions interact rather than reviewing tolerances individually.

A chain of dimensions can fail even when individual features pass
Worst-case arithmetic adds the maximum adverse contributions. If three independent contributors have ±0.10 mm, ±0.15 mm and ±0.05 mm tolerances, the worst-case total is ±0.30 mm, provided signs and geometry are treated consistently.
Technical method

For the same three contributors, root-sum-square gives sqrt(0.10² + 0.15² + 0.05²) ≈ 0.187 mm. This is a statistical approximation under assumptions of independence, appropriate distributions and process centering; it does not guarantee an assembly fit.
Worked situation and interpretation
Include nominal dimensions, direction of each contributor, datum relationships, geometric tolerances and actual assembly constraints. Statistical approaches may be inappropriate when severe consequences demand assured limits.
Why the common shortcut fails

Measured process distributions, correlations and shifting means change the interpretation. Never silently replace worst-case requirements with RSS to make a design look acceptable.
Where judgment is required
Validate critical fits with engineering analysis and physical measurements. Record assumptions and acceptance authority on the drawing or design review.
Building a defensible tolerance stack
- Identify the functional clearance or interference being evaluated.
- Assign each contributor’s direction, nominal dimension and tolerance limits.
- Calculate worst-case combinations before considering any statistical alternative.
- Use RSS only when the variation and independence assumptions are justified.
How to document the result
Document each contributing dimension with its nominal value, direction in the assembly chain, bilateral or asymmetric tolerance and datum relationship. Identify whether the model is worst-case, root-sum-square (RSS), a process-capability model or a simulation. State the assumptions rather than presenting a statistical result as a guaranteed bound.
Worked linear chain
For three nominal contributions of +10 mm, +5 mm and −3 mm, nominal stack is 12 mm. If their bilateral tolerances are ±0.10, ±0.15 and ±0.05 mm, worst-case variation is ±0.30 mm; the resulting interval is 11.70–12.30 mm. RSS variation is √(0.10² + 0.15² + 0.05²) ≈ 0.187 mm. This RSS value is only meaningful under the distributional and independence assumptions selected for the analysis.
Review whether dimension correlation, mean shifts, geometric tolerances, assembly deformation and thermal effects need separate treatment. Use the tolerance stack-up tool for an initial linear calculation and retain the approved engineering disposition alongside the drawing.
For connected manufacturing references, see Shop References, the Inspection Report Template and the practical guides. Choose the relevant standard and instrument before treating any example as a production rule.
Technical review note: Examples are for education and may simplify underlying standards. Engineering acceptance requires the applicable drawing, specification, calibrated methods and authorized review.
Frequently Asked Questions
What is worst-case tolerance stack-up?
It combines dimensional limits in the most unfavorable allowed directions to assess whether a specified fit or clearance can still be met.
How does statistical stack-up differ?
It estimates the distribution of combined variation using assumptions about individual processes and their relationships; it does not guarantee worst-case fit.
When should RSS analysis be avoided?
Do not rely on independent, centered and stable distributions when those assumptions are unverified or when a safety-critical interface requires hard-limit assurance.